  • 1
  • 2

Model Number : LWGYML

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Turbine Flowmeter

Power supply : 12VDC-24VDC or Battery Operated

Medium Temperature : -20℃~+110℃

Pipeline Diameter : DN4-DN200

Protection Class : IP65

Accuracy : ±1%R、±0.5%R、±0.2%R(Special Order)

Contact Now

LDC Display Industrial Flow Meter Battery Operated Hot Water Turbine Flow Metre

1. Introduction

LWGYML series intelligent liquid turbine Flowmeter is a new type of intelligent instrument with the integration of turbine flow sensor and display accumulation developed by advanced ultra-low power consumption single-chip microcomputer technology. it has the advantages of compact mechanism, intuitive and clear reading, high reliability, no interference from external power supply, anti-lightning strike, low cost and so on.

It is widely used in the sealed pipelines which doesn’t have corrosion function on SS 1Cr18Ni9Ti, 2Cr13, corundum Al2O3 and cemented carbide and have no fiber, particle and so on. The liquid should be less than 5*10-6m2/s with viscosity under working temperature, if the viscosity of the liquid is more than 5*10-6m2/s, then the flow meter can be used after calibration. If it is equipped with other display devices with special functions, it can also do quantity control, excessive alarm and so on. It is really perfect in flow measurement and energy

conservation.

2. Features

  • High accuracy, usually reach ±1%R,±0.5%R,or even reach ±0.2%R for high-precision type.
  • Good repeatability, it can reach 0.05%-0.2% in short term, if regular calibration or online calibration can get an extremely high accuracy, so it is preferred in foreign trade.
  • Pulse signal output, it is suitable for totalizer measurement and computer connection, no zero drift,strong capacity of resisting disturbance.
  • High frequency signal(3-4KHz), strong signal resolution.
  • Wide range, middle and big diameter can reach 1:20, and small diameter can reach 1:10.
  • Compact structure, easy installation and maintenance.

3. Working Principle

Working principle of turbine flowmeter: the fluid flows through the sensor housing. Because the impeller blades have a certain angle with the flow direction, the impulse force of the fluid makes the blades have a rotating moment. After overcoming the friction moment and fluid resistance, the blades rotate. After the moment is balanced, the rotating speed is stable. Under certain conditions, the rotating speed is directly proportional to the flow velocity. Because the blades have magnetic conductivity, they are in the magnetic field of the signal detector (composed of permanent magnetic steel and coils), and the rotating blades cut magnetic lines. The magnetic flux of the coil is changed periodically, so that the electric pulse signal is induced at both ends of the coil. This signal is amplified and shaped by an amplifier to form a continuous rectangular pulse wave with a certain amplitude, which can be transmitted to the display instrument remotely to display the instantaneous flow rate and accumulated amount of fluid.

4. Specifications

Pipeline Diameter(mm)
and
Connection
4,6,10,15,20,25,32,40
Thread Connection
(15,20,25,32,40) 50,65,80,100,125,150,200
Flange Connection
Accuracy ±1%R,±0.5%R,±0.2%R(Special Order)
Turn Down Ratio 10:1; 15:1; 20:1
Material 304SS,316(L)SS, etc
Medium Temperature -20℃~+110℃
Environmental Conditions Temperature: -10℃~+55℃
Relative humidity: 5%~90%
Atmospheric pressure: 86~106KPa
Power supply Sensor:+12VDC,+24VDC(Option)
Transmitter:+24VDC
Local Display:3.2V Lithium Battery
Output Signal Sensor:Pulse Frequency Signal(Low level≤0.8V, High level≥8V)
Transmitter:Two Wired 4-20mA Current Signal
Signal Cable STVPV 3x0.3(Three Wired),2x0.3(Two Wired)
Signal Cable Connection Houseman Connector(Standard Type)
Inner Thread M20x1.5(Explosion Type)
Transmission Distance ≤1000m
Explosion Proof None(Standard Type)
EXdIIBT6(Explosion Proof)
Protection Class IP65

5. Flow Range & Work Pressure

Pipeline Diameter Normal Flow Range
(m³/h)
Extended Flow Range
(m³/h)
Normal Pressure
(MPa)
Pressure Rate(MPa)
(Flange Connection)
DN4 0.04~0.25 0.04~0.40 6.3 12,16,25
DN6 0.10~0.60 0.06~0.60 6.3 12,16,25
DN10 0.20~1.20 0.15~1.50 6.3 12,16,25
DN15 0.60~6.00 0.40~8.00 6.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN20 0.80~8.00 0.45~9.00 6.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN25 1.00~10.00 0.50~10.00 6.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN32 1.50~15.00 0.80~15.00 6.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN40 2.00~20.00 1.00~20.00 6.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN50 4.00~40.00 2.00~~40.00 2.5 4.0,6.3,12,16,25
DN65 7.00~70.00 4.00~70.00 2.5 4.0,6.3,12,16,25
DN80 10.00~100.00 5.00~100.00 2.5 4.0,6.3,12,16,25
DN100 20.00~200.00 10.00~200.00 1.6 4.0,6.3,12,16,25
DN125 25.00~250.00 13.00~250.00 1.6 2.5,4.0,6.3,12,16
DN150 30.00~300.00 15.00~300.00 1.6 2.5,4.0,6.3,12,16
DN200 80.00~800.00 40.00~800.00 1.6 2.5,4.0,6.3,12,16

6. Configuration

LWGYML Series Turbine Flow Meter Configuration
Model LWGYML
Pipe Material 4 4mm
6 6mm
10 10mm
......
200 200mm
Model Description N No Display,12VDC Power Supply,Pulse Output, High Level≥8V Low Level≤0.8V
A No Display,4-20mA 2 Wired Current Output
B Local Display,Battery Operated
C Local Display,4-20mA 2 Wired Current Output
C1 Local Display,RS485 Output
C2 Local Display, HART Output
Accuracy 05 0.5 Grade
10 1.0 Grade
Turbine Type W Extended Ratio
S Standard Ratio
Material S SS 304
I SS 316(L)
Explosion Proof N None
E Explosion Type(ExmIICT6 or ExdIIBT6)
Pressure Rate N Normal Pressure
H High Pressure
Connection Type T Thread Connection
F Flange Connection
Filter N None
F With Filter

7. Product Details

LCD Display Industrial Flow Meter Battery Operated Hot Water Turbine Flow Metre


Product Tags:

vortex air flow meter

      

vortex flow transmitter

      
Buy cheap LCD Display Industrial Flow Meter Battery Operated Hot Water Turbine Flow Metre product

LCD Display Industrial Flow Meter Battery Operated Hot Water Turbine Flow Metre Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)